Had to install coating on a rusted roof.
Northwoods Convention Center
Duro-Last® Prefabricated Vinyl Roofing
Had to install coating on a rusted roof.
Northwoods Convention Center
Duro-Last® Prefabricated Vinyl Roofing
Northwoods Convention Center had leaking ribs, especially with ice dams in the winter time. We installed tapered insulation between the ribs, fanfold insulation across the entire roof, and a white Duro-Last® membrane.
Northwoods Convention Center
Duro-Last® Prefabricated Vinyl Roofing
The roof had a failing Built Up Roof (BUR) and we needed to make deck repairs due to rot.
We tore off the BUR and installed fan fold insulation with a 50 mil white Duro-Last roof.
Cranberry Creek Pumphouse
Duro-Last® Prefabricated Vinyl Roofing
Olympic II Family Restaurant previously had a ribbed roof that leaked because of ice dams and penetrations. From the beginning we knew that vegetable and meat oils coming from vents needed to be taken into consideration. Something many roofing companies overlook is the fact that these oils can rapidly deteriorate a roofing system. We first insulated the roof by filling the ribs with tapered insulation and 3 inches of ISO board stock. Next, we installed a Terra Cotta Duro-Last® PVC membrane to provide superior protection against weather and destructive cooking oils.
Olympic II Family Restaurant
Duro-Last® Prefabricated Vinyl Roofing
Valley Screen Print had a failing EPDM membrane. We installed a 50 mil light Gray Duro-last membrane directly over the failing EPDM.
We also had to remove and re-install a shingled valley as part of this process.
Valley Screen Print
Duro-Last® Prefabricated Vinyl Roofing
Mid-States had 3″ mechanically applied ISO board insulation with a fully adhered EPDM roof. Over the years, the facer on the insulation had deteriorated and the delaminated EPDM was blowing off in the wind.
We installed fanfold insulation with a mechanically installed 50 mil Duro-Last® membrane including a Duro-Last® parapet membrane.
Mid-States Aluminum Fond du Lac, WI
Duro-Last® Prefabricated Vinyl Roofing
Auto Select had a fully adhered EPDM membrane on an under-insulated and leaking roof. There were failing seams and rakes leaked badly.
We installed a 3″ staggered ISO insulated deck with a 50 mil white Duro-Last® membrane.
Auto Select Stevens Point, WI
Duro-Last® Prefabricated Vinyl Roofing